Home/ Projects/ KleanNara-Demi.Water System
Reference · Pure Water · 2021.06

KleanNara-Demi.Water System.

Pure Water UF RO H/E CIP Korea
SummarySupply of a 100 m³/hr pure water treatment facility, including Ultrafiltration (UF), Reverse Osmosis (RO), and auxiliary systems.

Supply of a 100 m³/hr pure water treatment facility, including Ultrafiltration (UF), Reverse Osmosis (RO), and auxiliary systems.

Project · Overview

Design · fabrication · commissioning.

Installation of a pure water (RO) system at the KleanNara Cheongju plant through Nongshim Engineering. Execution of mechanical equipment procurement/manufacturing, piping/mechanical installation, electrical/instrumentation works, and commissioning for the Ultrafiltration (UF) unit, Reverse Osmosis (RO) unit, Heat Exchanger, chemical dosing system (NaOCl, SBS, Scale Inhibitor), and CIP System.

Highlights

What this project proved.

  • 100 m³/hr (Configured with two 50 m³/hr operating trains and one standby train)
  • RO Recovery Rate: 75%
  • Pre-treatment: UF (Hollow Fiber, 0.02µm, Inge Dizzer) and Plate Heat Exchanger
  • RO module consisting of 60 elements per unit (Array 6:4)
  • Application of CIP System, chemical dosing system, and Booster System
Back to all references